Exposure In Industrial Radiography
Industrial Radiography

Exposure is done at the floor, in the center of each room and in the same source's vertical plane.
1- Point isotropic source was considered.
2- Build-up factors for gamma energies over 500 keV were calculated using Taylor's equation.
3- Build-up factors for gamma energies between 100 keV and 500 keV were calculated using Trubey's table.
Copyright © December 2009 University of Toronto
Not to be reproduced without the written permission of the Office of Environmental Health and Safety
215 Huron Street, Toronto, Ontario, Canada M5S 1A2